Applied sciences

Metrology and Measurement Systems

Content

Metrology and Measurement Systems | 2019 | vol. 26 | No 1 |

Abstract

The main points of the UPoN-2018 talk and some valuable comments from the Audience are briefly summarized. The talk surveyed the major issues with the notion of zero-point thermal noise in resistors and its visibility; moreover it gave some new arguments. The new arguments support the old view of Kleen that the known measurement data “showing” zero-point Johnson noise are instrumental artifacts caused by the energy-time uncertainty principle. We pointed out that, during the spectral analysis of blackbody radiation, another uncertainty principle is relevant, that is, the location-momentum uncertainty principle that causes only the widening of spectral lines instead of the zero-point noise artifact. This is the reason why the Planck formula is correctly confirmed by the blackbody radiation experiments. Finally a conjecture about the zero-point noise spectrum of wide-band amplifiers is shown, but that is yet to be tested experimentally.

Go to article

Abstract

Low-frequency noise measurements have long been recognized as a valuable tool in the examination of quality and reliability of metallic interconnections in the microelectronic industry. While characterized by very high sensitivity, low-frequency noise measurements can be extremely time-consuming, especially when tests have to be carried out over an extended temperature range and with high temperature resolution as it is required by some advanced characterization approaches recently proposed in the literature. In order to address this issue we designed a dedicated system for the characterization of the low-frequency noise produced by a metallic line vs temperature. The system combines high flexibility and automation with excellent background noise levels. Test temperatures range from ambient temperature up to 300◦C. Measurements can be completely automated with temperature changing in pre-programmed steps. A ramp temperature mode is also possible that can be used, with proper caution, to virtually obtain a continuous plot of noise parameters vs temperature.

Go to article

Abstract

The paper presents a proposal of using additional statistical parameters such as: standard deviation, variance, maximum and minimum increases of the observed value that were determined during measurements of temperature fields created on the surface of the tested electrochemical capacitor. The measurements were carried out using thermographic methods in order to support assessment of the condition of electrochemical capacitor under classic durability tests based on methods of determination of capacity and equivalent series resistance. The possibility of using some statistical parameters in assessment of the electrochemical capacitor quality was illustrated. The applied measurement methodology and the results of research associated with the classic methods of supercapacitors’ assessment are presented. The obtained results indicate that the variability of some statistical parameters of temperature fields can be directly related to changing the values of standard parameters describing electrochemical capacitor, which are capacitance and equivalent series resistance.

Go to article

Abstract

The Kirchhoff-law-Johnson-noise (KLJN) secure key exchange scheme offers unconditional security, however it can approach the perfect security limit only in the case when the practical system’s parameters approach the ideal behavior of its core circuitry. In the case of non-ideal features, non-zero information leak is present. The study of such leaks is important for a proper design of practical KLJN systems and their privacy amplifications in order to eliminate these problems.

Go to article

Abstract

Compact radiators with circular polarization are important components of modern mobile communication systems. Their design is a challenging process which requires maintaining simultaneous control over several performance figures but also the structure size. In this work, a novel design framework for multi-stage constrained miniaturization of antennas with circular polarization is presented. The method involves se- quential optimization of the radiator in respect of selected performance figures and, eventually, the size. Optimizations are performed with iteratively increased number of design constraints. Numerical efficiency of the method is ensured using a fast local-search algorithm embedded in a trust-region framework. The proposed design framework is demonstrated using a compact planar radiator with circular polarization. The optimized antenna is characterized by a small size of 271 mm2 with 37% and 47% bandwidths in respect of 10 dB return loss and 3 dB axial ratio, respectively. The structure is benchmarked against the state-of-the-art circular polarization antennas. Numerical results are confirmed by measurements of the fabricated antenna prototype.

Go to article

Abstract

This paper describes a synthetic aperture radar system for tactical-level imagery intelligence installed on board an unmanned aerial vehicle. Selected results of its tests are provided. The system contains interchange-able S-band and Ku-band linear frequency-modulated, continuous wave radar sensors that were built within a frame of a research project named WATSAR, conducted by the Military University of Technology and WB Electronics S.A. One of several algorithms of radar image synthesis, implemented in the scope of the project, is described in this paper. The WATSAR system can create online and off-line radar images.

Go to article

Abstract

Malignant melanomas are the most deadly type of skin cancer, yet detected early have high chances of successful treatment. In the last twenty years, the interest in automatic recognition and classification of melanoma dynamically increased, partly because of appearing public datasets with dermatoscopic images of skin lesions. Automated computer-aided skin cancer detection in dermatoscopic images is a very challenging task due to uneven sizes of datasets, huge intra-class variation with small interclass variation, and the existence of many artifacts in the images. One of the most recognized methods of melanoma diagnosis is the ABCD method. In the paper, we propose an extended version of this method and an intelligent decision support system based on neural networks that uses its results in the form of hand-crafted features. Automatic determination of the skin features with the ABCD method is difficult due to the large diversity of images of various quality, the existence of hair, different markers and other obstacles. Therefore, it was necessary to apply advanced methods of pre-processing the images. The proposed system is an ensemble of ten neural networks working in parallel, and one network using their results to generate a final decision. This system structure enables to increase the efficiency of its operation by several percentage points compared with a single neural network. The proposed system is trained on over 5000 and tested afterwards on 200 skin moles. The presented system can be used as a decision support system for primary care physicians, as a system capable of self-examination of the skin with a dermatoscope and also as an important tool to improve biopsy decision making.

Go to article

Abstract

In this paper the authors propose a decision support system for automatic blood smear analysis based on microscopic images. The images are pre-processed in order to remove irrelevant elements and to enhance the most important ones – the healthy blood cells (erythrocytes) and the pathologic ones (echinocytes). The separated blood cells are analysed in terms of their most important features by the eigenfaces method. The features are the basis for designing the neural network classifier, learned to distinguish between erythrocytes and echinocytes. As the result, the proposed system is able to analyse the smear blood images in a fully automatic way and to deliver information on the number and statistics of the red blood cells, both healthy and pathologic. The system was examined in two case studies, involving the canine and human blood, and then consulted with the experienced medicine specialists. The accuracy of classification of red blood cells into erythrocytes and echinocytes reaches 96%.

Go to article

Abstract

The paper presents a method of obtaining short-termpositioning accuracy based on micro electro-mechanical system (MEMS) sensors and analysis of the results. A high-accuracy and fast-positioning algorithm must be included due to the high risk of accidents in cities in the future, especially when autonomous objects are taken into account. High-level positioning systems should consider a number of sub-systems such as global positioning system (GPS), CCTV – video analysis, a system based on analysis of signal strength of access points (AP), etc. Short-term positioning means that there are other locating systems with a sufficiently high degree of accuracy based on, e.g. a video camera, but the located object can disappear when it is hidden by other objects, e.g. people, things, shelves etc. In such a case, MEMS sensors can be employed as a positioning system. The paper examines typical movement profiles of a radio-controlled (RC) model and fundamental filtering methods in respect of position accuracy. The authors evaluate the complexity and delay of the filter and the accuracy of the positioning in respect of the current speed and phase of movement (positive acceleration, constant) of the object. It is necessary to know whether and how the length of the filter changes the position accuracy. It has been shown that the use of fundamental filters, which provide solutions in a short time, enables to locate objects with a small error in a limited time.

Go to article

Abstract

A revision of the standard approach to characterization of thin-semiconductor-layer Hall samples has been proposed. Our results show that simple checking of I(V) curve linearity at room temperature might be insufficient for correct determination of bias conditions of a sample before measurements of Hall effect. It is caused by the nonlinear behaviour of electrical contact layers, which should be treated together with the tested layer a priori as a metal-semiconductor-metal (MSM) structure. Our approach was examined with a Be-doped p-type InAs epitaxial layer, with four gold contacts. Despite using full high-quality photolithography a significant asymmetry in maximum differential resistance (Rd) values and positions relative to zero voltage (or current) value was observed for different contacts. This suggests that such characterization should be performed before each high-precision magneto-transport measurement in order to optimize the bias conditions.

Go to article

Abstract

In this paper, we propose and experimentally demonstrate a new method for optical frequency transfer over fibre. Instead of dual acousto-optic modulators (AOMs) as adopted in the traditional fibre phase noise compensation setup, here an active fibre phase noise compensation scheme with a single acousto-optic modulator (AOM) is used. The configuration simplifies the equipment of the user end while maintaining a high-performance optical frequency transfer stability. We demonstrate an actively stabilized coherent transfer at an optical frequency of 193.55THz over 10-km spooled fibre, obtaining a relative frequency stability (Allan deviation) of 3:84  10��16/1 s and 4:08  10��18/104 s, which is improved by about 23 orders of magnitude in comparison with the one without any phase noise compensation that achieves a relative frequency stability of 1:81  10��14/1 s and 2:48  10��15/104 s.

Go to article

Abstract

Many researchers have contributed to creating Quantum Key Distribution (QKD) since the first protocol BB84 was proposed in 1984. One of the crucial problems in QKD is to guarantee its security with finite-key lengths by Privacy Amplification (PA). However, finite-key analyses show a trade-off between the security of BB84 and the secure key rates. This study analyses two examples to show concrete trade-offs. Furthermore, even though the QKD keys have been perceived to be arbitrarily secure, this study shows a fundamental limitation in the security of the keys by connecting Leftover Hash Lemma and Guessing Secrecy on the QKD keys.

Go to article

Abstract

In recent years, many scientific and industrial centres in the world developed virtual reality systems or laboratories. At present, among the most advanced virtual reality systems are CAVE-type (Cave Automatic Virtual Environment) installations. Such systems usually consist of four, five, or six projection screens arranged in the form of a closed or hemi-closed space. The basic task of such systems is to ensure the effect of user “immersion” in the surrounding environment. The effect of user “immersion” into virtual reality in such systems is largely dependent on optical properties of the system, especially on quality of projection of three-dimensional images. In this paper, techniques of projection of three-dimensional (3D) images in CAVE-type virtual reality systems are analysed. The requirements of these techniques for such virtual reality systems are outlined. Based on the results of measurements performed in a unique CAVE-type virtual reality laboratory equipped with two different 3D projection techniques, named Immersive 3D Visualization Lab (I3DVL), that was recently opened at the Gdańsk University of Technology, the stereoscopic parameters and colour gamut of Infitec and Active Stereo stereoscopic projection techniques are examined and discussed. The obtained results enable to estimate the projection system quality for application in CAVE-type virtual reality installations.

Go to article

Abstract

In this paper we describe our own construction of a tuneable light source based on a set of light emitting diodes covering the visible spectrum using a homogenizing rod instead commonly used low energy-efficient integrating spheres. The expected prime application of the source is a medical endoscopic system, however it is possible to use it also for other purposes requiring both multispectral operation and a tuneable white light source. We describe the construction of the source and include precise characterization of the output white light – distribution of CCT, Duv, Δu′ v ′ and colour rendering indexes (Ra, R9, Rf , Rg) of light in several planes located at various distances. The obtained results prove that our source is characterized by very good colour rendition according to the Ra and Rf method for various correlated colour temperatures (2700–6500) K. As an example of application images of the Macbeth colour chart registered with an RGB camera included in the laboratory measurement stand are presented. The obtained results prove that, after whole system calibration, this source can be used in many applications, where evaluation of objects requires precise analysis of their colour and multispectral procedures.

Go to article

Abstract

According to metrological guidelines and specific legal requirements, every smart electronic electricity meter has to be constantly verified after pre-defined regular time intervals. The problem is that in most cases these pre-defined time intervals are based on some previous experience or empirical knowledge and rarely on scientifically sound data. Since the verification itself is a costly procedure it would be advantageous to put more effort into defining the required verification periods. Therefore, a fixed verification interval, recommended by various internal documents, standardised evaluation procedures and national legislation, could be technically and scientifically more justified and consequently more appropriate and trustworthy for the end user. This paper describes an experiment to determine the effect of alternating temperature and humidity and constant high current on a smart electronic electricity meter’s measurement accuracy. Based on an analysis of these effects it is proposed that the current fixed verification interval could be revised, taking into account also different climatic influence. The findings of this work could influence a new standardized procedure in respect of a meter’s verification interval.

Go to article

Abstract

Reliable estimation of longitudinal force and sideslip angle is essential for vehicle stability and active safety control. This paper presents a novel longitudinal force and sideslip angle estimation method for four-wheel independent-drive electric vehicles in which the cascaded multi-Kalman filters are applied. Also, a modified tire model is proposed to improve the accuracy and reliability of sideslip angle estimation. In the design of longitudinal force observer, considering that the longitudinal force is the unknown input of the electric driving wheel model, an expanded electric driving wheel model is presented and the longitudinal force is obtained by a strong tracking filter. Based on the longitudinal force observer, taking into consideration uncertain interferences of the vehicle dynamic model, a sideslip angle estimation method is designed using the robust Kalman filter and a novel modified tire model is proposed to correct the original tire model using the estimation results of longitudinal tire forces. Simulations and experiments were carried out, and effectiveness of the proposed estimation method was verified.

Go to article

Editorial office

Editor-in-Chief
  • Janusz SMULKO, Gdańsk University of Technology, Poland
International Programme Committee
  • Andrzej ZAJĄC, Chairman, Military University of Technology, Poland
  • Bruno ANDO, University of Catania, Italy
  • Martin BURGHOFF, Physikalisch-Technische Bundesanstalt, Germany
  • Marcantonio CATELANI, University of Florence, Italy
  • Numan DURAKBASA, Vienna University of Technology, Austria
  • Domenico GRIMALDI, University of Calabria, Italy
  • Laszlo KISH, Texas A&M University, USA
  • Eduard LLOBET, Universitat Rovira i Virgili, Tarragona, Spain
  • Alex MASON, Liverpool John Moores University, The United Kingdom
  • Subhas MUKHOPADHYAY, Massey University, Palmerston North, New Zealand
  • Janusz MROCZKA, Wrocław University of Technology, Poland
  • Antoni ROGALSKI, Military University of Technology, Poland
  • Wiesław WOLIŃSKI, Warsaw University of Technology, Poland
Associate Editors
  • Zbigniew BIELECKI, Military University of Technology, Poland
  • Vladimir DIMCHEV, Ss. Cyril and Methodius University, Macedonia
  • Krzysztof DUDA, AGH University of Science and Technology, Poland
  • Janusz GAJDA, AGH University of Science and Technology, Poland
  • Teodor GOTSZALK, Wrocław University of Technology, Poland
  • Ireneusz JABŁOŃSKI, Wrocław University of Technology, Poland
  • Piotr JASIŃSKI, Gdańsk University of Technology, Poland
  • Piotr KISAŁA, Lublin University of Technology, Poland
  • Manoj KUMAR, University of Hyderabad, Telangana, India
  • Grzegorz LENTKA, Gdańsk University of Technology, Poland
  • Czesław ŁUKIANOWICZ, Koszalin University of Technology, Poland
  • Rosario MORELLO, University Mediterranean of Reggio Calabria, Italy
  • Fernando PUENTE LEÓN, University Karlsruhe, Germany
  • Petr SEDLAK, Brno University of Technology, Czech Republic
  • Hamid M. SEDIGHI, Shahid Chamran University of Ahvaz, Ahvaz, Iran
  • Roman SZEWCZYK, Warsaw University of Technology, Poland
Language Editors
  • Andrzej Stankiewicz, Gdańsk University of Technology, Poland
Technical Editors
  • Agnieszka Kondratowicz, Gdańsk University of Technology, Poland

Contact

Editorial Office of Metrology and Measurement Systems

Contact:
E-mail: metrology@pg.edu.pl
URL: www.metrology.pg.gda.pl
Phone: (+48) 58 347-1357

Post address:
Editorial Office of Metrology and Measurement Systems
Gdańsk University of Technology, Faculty of Electronics, Telecommunications and Informatics

Instructions for authors

Types of contributions

The following types of papers are published in Metrology and Measurement Systems:
•    invited review papers presenting the current stage of the knowledge (max. 20 edited pages, 3000 characters each),
•    research papers reporting original scientific or technological advancements (10‒12 pages),
•    papers based on extended and updated contributions presented at scientific conferences (max. 12 pages),
•    short notes, i.e. book reviews, conference reports, short news (max. 2 pages).

Manuscript preparation

The text of a manuscript should be written in clear and concise English. The form similar to “camera-ready” with an attached separate file – containing illustrations, tables and photographs – is preferred. For the details of the preferred format of the manuscripts, Authors should consult a recent issue of the journal or the sample article and the guidelines for manuscript preparation. The text of a manuscript should be printed on A4 pages (with margins of 2.5 cm) using a font whose size is 12 pt for main text and 10 pt for the abstract; an even number of pages is strongly recommended. The main text of a paper can be divided into sections (numbered 1, 2, ...), subsections (numbered 1.1., 1.2., ...) and – if needed – paragraphs (numbered 1.1.1., 1.1.2., ...). The title page should include: manuscript title, Authors’ names and affiliations with e-mail addresses. The corresponding Author should be identified by the symbol of an envelope and phone number. A concise abstract of approximately 100 words and with 3–5 keywords should accompany the main text.
Illustrations, photographs and tables provided in the camera-ready form, suitable for reproduction (which may include reduction) should be additionally submitted one per page, larger than final size. All illustrations should be clearly marked on the back with figure number and author’s name. All figures are to have captions. The list of figures captions and table titles should be supplied on separate page. Illustrations must be produced in black ink on white paper or by computer technique using the laser printer with the resolution not lower than 300 dpi, preferably 600 dpi. The thickness of lines should be in the range 0.2–0.5 mm, in particular cases the range 0.1–1.0 mm will be accepted. Original photographs must be supplied as they are to be reproduced (e.g. black and white or colour). Photocopies of photographs are not acceptable.
References should be inserted in the text in square brackets, e.g. [4]; their list numbered in citation order should appear at the end of the manuscript. The format of the references should be as follows: for a journal paper – surname(s) and initial(s) of author(s), year in brackets, title of the paper, journal name (in italics), volume, issue and page numbers. The exemplary format of the references is available at the sample article.

Manuscript submission and processing

Submission procedure. Manuscript should be submitted via Internet Editorial System (IES) ‒ an online submission and peer review system http://www.editorialsystem.com/mms
In order to submit the manuscript via IES, the authors (first-time users) must create an author account to obtain a user ID and password required to enter the system. From the account you create, you will be able to monitor your submission and make subsequent submissions.
The submission of the manuscript in two files is preferred: “Paper File” containing the complete manuscript (with all figures and tables embedded in the text) and “Figures File” containing illustrations, photographs and tables. Both files should be sent in DOC and PDF format as well as. In the submission letter or on separate page in “Figures File”, the full postal address, e-mail and phone numbers must be given for all co-authors. The corresponding Author should be identified.
Copyright Transfer. The submission of a manuscript means that it has not been published previously in the same form, that it is not under consideration for publication elsewhere, and that – if accepted – it will not be published elsewhere. The Author hereby grants the Polish Academy of Sciences (the Journal Owner) the license for commercial use of the article according to the Open Access License which has to be signed before publication.
Review and amendment procedures. Each submitted manuscript is subject to a peer-review procedure, and the publication decision is based on reviewers’ comments; if necessary, Authors may be invited to revise their manuscripts. On acceptance, manuscripts are subject to editorial amendment to suit the journal style.
An essential criterion for the evaluation of submitted manuscripts is their potential impact on the scientific community, measured by the number of repeated quotations. Such papers are preferred at the evaluation and publication stages.
Proofs. Proofs will be sent to the corresponding Author by e-mail and should be returned within 48 hours of receipt.

Other information

Author Benefits. The publication in the journal is free of charge. A sample copy of the journal will be sent to the corresponding Author free of charge.
Colour. For colour pages the Authors will be charged at the rate of 160 PLN or 80 EUR per page. The payment to the bank account of main distributor must be acquitted before the date pointed to Authors by Editorial Office.

This page uses 'cookies'. Learn more