Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 9
items per page: 25 50 75
Sort by:

Abstract

The paper presents results of the field tests on membrane biogas enrichment performed with the application of mobile membrane installation (MMI) with the feed stream up to 10 Nm3/h. The mobile installation equipped with four hollow fibre modules with polyimide type membranes was tested at four different biogas plants. Two of them were using agricultural substrates. The third one was constructed at a municipal wastewater plant and sludge was fermented in a digester and finally in the fourth case biogas was extracted from municipal waste landfill site. Differences in the concentration of bio-methane in feed in all cases were observed and trace compounds were detected as well. High selectivity polyimide membranes, in proper module arrangements, can provide a product of high methane content in all cases. The content of other trace compounds, such as hydrogen sulphide, water vapour and oxygen on the product did not exceed the values stated by standard for a biogas as a vehicle fuel. The traces of hydrogen sulphide and water vapour penetrated faster to the waste stream enriched in carbon dioxide, which could lead to further purification of the product – methane being hold in the retentate (H2O > H2S > CO2 > O2 > CH4 > N2). In the investigated cases, when concentration of N2 was low and concentration of CH4 higher than 50%, it was possible to upgrade methane to concentration above 90% in a two-stage cascade. To performsimulation ofCH4 andCO2 permeation through polyimide membrane,MATLABwas used. Simulation program has included permeation gaseous mixture with methane contents as observed at field tests in the range of 50 and 60% vol. The mass transport process was estimated for a concurrent hollow fibre membrane module for given pressure and temperature conditions and different values of stage cut. The obtained results show good agreement with the experimental data. The highest degree of methane recovery was obtained with gas concentrating in a cascade with recycling of the retentate.
Go to article

Abstract

The aim of this work was to investigate the influence of distilled water flowrate in two different porousmembrane modules on the size of generated nitrogen nanobubbles. Modules had different diameter and number of membrane tubes inside the module. As bubbles are cut off from the membrane surface by a shear stress induced by the liquid flow, the change in the linear liquid velocity should result in a change of the generated bubble diameter. For both modules, higher flowrate of liquid induced generation of smaller bubbles, which was consistent with our expectations. This effect can help us in generation of bubbles of desired size.
Go to article

Abstract

The paper presents the experimental study of a novel unsteady-statemembrane gas separation approach for recovery of a slow-permeant component in the membrane module with periodical retentate withdrawals. The case study consisted in the separation of binary test mixtures based on the fast-permeant main component (N2O, C2H2) and the slow-permeant impurity (1%vol. of N2) using a radial countercurrent membrane module. The novel semi-batch withdrawal technique was shown to intensify the separation process and provide up to 40% increase in separation efficiency compared to a steady-state operation of the same productivity.
Go to article

Abstract

This paper presents ultrafiltration results of model BSA (bovine serum albumin) and MB (myoglobin) solutions prepared with or without NaCl addition. The protein concentrations in the solutions were equal to 0.05 g#1;dm􀀀3 for MB and 0.5 g#1;dm􀀀3 for BSA. The ultrafiltration tests were performed using a laboratory scale unit equipped with 90 mm ceramic disc membranes with a filtration area of 5:6#2;10􀀀3 m2 and cut-off of 50 or 150 kDa. The tests were run under constant process conditions, i.e. a cross flow volume (CFV) of 5 m#1;s􀀀1, transmembrane pressure (TMP) of 0.2 MPa, temperature of 20 ◦C and NaCl concentration of 0 or 10 wt%. The installation worked in a semi-open mode with a continuous permeate discharge and retentate recycle. The performance of the membranes was measured with the permeate volumetric flow rate, JV (m3m􀀀2s􀀀1) while their selectivity was determined by the protein rejection, R. The paper evaluates and discusses the protein rejection mechanisms as well as the influence of the membrane cut-off and sodium chloride concentration in the feed on the flux decline during the ultrafiltration of BSA and MB. Moreover, it provides an analysis of the first fouling phase by applying usual filtration laws.
Go to article

Abstract

This paper presents the recent advances in pervaporative reduction of sulfur content in gasoline. Methods of preliminary selection of membrane active layer material are presented. Interactions between gasoline components (typical hydrocarbon and sulfur species) and membranes are showed. Influence of pervaporation process parameters i.e. feed temperature, downstream pressure and feed flow rate on the separation efficiency is discussed. Investigations of the influence of sulfur concentration in fluid catalytic cracking (FCC) gasoline on membrane performance have been conducted. A series of PV tests was carried out to investigate the separation properties of the commercial composite membrane with an active layer made of poly(dimethylsiloxane) and to determine the efficiency of organic sulphur compound (thiophene) removal from model thiophene/n-heptane mixture depending on its concentration.
Go to article

Abstract

CO2 emission from combustion fossil fuels is considered as the primary factor in the global warming. Different methods for separation CO2 from combustion flue gases are extensively used across the world. The aim of this study is to analyze the most important technological solutions of CO2 separation. For this reason chemical absorption, physical absorption, adsorption approach, membrane filtration and cryogenic process were researched. Concluding, selection of the right method for carbon dioxide capture separation is a complex issue and a range of technological and economic factors should be taken into consideration prior to application on the industrial scale.
Go to article

Abstract

The influence of ion implantation on the structure and properties of polymers is a very complex issue. Many physical and chemical processes taking place during ion bombardment must be taken into consideration. The complexity of the process may exert both positive and negative influence on the structure of the material. The goal of this paper is to investigate the influence of H+, He+ and Ar+ ion implantation on the properties of polypropylene membranes used in filtration processes and in consequence on fouling phenomena. It has appeared that the ion bombardment caused the chemical modification of membranes which has led to decrease of hydrophobicity. The increase of protein adsorption on membrane surface has also been observed.
Go to article

Abstract

The paper presents the basic input data and modelling results of IGCC system with membrane CO2 capture installation and without capture. The models were built using commercial software (Aspen and GateCycle) and with the use of authors’ own computational codes. The main parameters of the systems were calculated, such as gross and net power, auxiliary power of individual installations and efficiencies. The models were used for the economic and ecological analysis of the systems. The Break Even Point method of analysis was used. The calculations took into account the EU emissions trading scheme. Sensitivity analysis on the influence of selected quantities on break-even price of electricity was performed
Go to article

Abstract

The application of immune serum is one of the most efficient method used formerly in the protection of raised piglets’/weaners’ health . The objective of the study was to determine specific antibody response during hyperimmunization of fatteners with a self-prepared subunit vaccine, and to propose production method of immune serum against Gram-negative bacteria antigens. The vaccine was administered every two weeks, 4 times. Individual and pooled serum samples were assayed for IgM, IgG and IgA antibodies against Histophilus somni recombinant Hsp60, H.somni rOMP40 and Pasteurella multocida LPS. Additionally total serum IgG and haptoglobin concentrations were measured. Two weeks after the first vaccination IgM antibody raised significantly against H.s. rOMP40 and LPS, whereas after 4 weeks it increased against rHsp60 antigens. Anti-LPS IgM antibody raised up stepwise till the end of the observation, but IgM antibody against H.s. rHsp60 and H.s. rOMP40 decreased in further samplings. A significant raise in IgG class H.s. rHsp60- -antibody was found 4 weeks after the first immunization and a similar raise against two remain- ing antigens after 6 weeks. The intensity of the reaction increased till the end of the experiment. The raise in IgA antibody level was observed only for H.s. rHsp60 antigen. Clinically observed, proper animal health and welfare were confirmed by haptoglobin concentration, which remained in physiological range. At least 4 booster doses were necessary to obtain hyperimmune serum containing a high level of antibodies against examined antigens. The number of immunizations influenced response profiles for specific IgM, IgG, IgA antibodies.
Go to article

This page uses 'cookies'. Learn more