Search results

Filters

  • Journals
  • Date

Search results

Number of results: 3
items per page: 25 50 75
Sort by:

Abstract

Current power grid and market development, characterized by large growth of distributed energy sources in recent years, especially in Europa, are according energy storage systems an increasingly larger field of implementation. Existing storage technologies, e.g. pumped-storage power plants, have to be upgraded and extended by new but not yet commercially viable technologies (e.g. batteries or adiabatic compressed air energy storage) that meet expected demands. Optimal sizing of storage systems and technically and economically optimal operating strategies are the major challenges to the integration of such systems in the future smart grid. This paper surveys firstly the literature on the latest niche applications. Then, potential new use case and operating scenarios for energy storage systems in smart grids, which have been field tested, are presented and discussed and subsequently assessed technically and economically.
Go to article

Abstract

Both the growing number of dispersed generation plants and storage systems and the new roles and functions on the demand side (e.g. demand side management) are making the operation (monitoring and control) of electrical grids more complex, especially in distribution. This paper demonstrates how to integrate phasor measurements so that state estimation in a distribution grid profits optimally from the high accuracy of PMUs. Different measurement configurations consisting of conventional and synchronous mea- surement units, each with different fault tolerances for the quality of the calculated system state achieved, are analyzed and compared. Weighted least squares (WLS) algorithms for conventional, linear and hybrid state estimation provide the mathematical method used in this paper. A case study of an 18-bus test grid with real measured PMU data from a 110 kV distribution grid demonstrates the improving of the system’s state variable’s quality by using synchrophasors. The increased requirements, which are the prerequisite for the use of PMUs in the distribution grid, are identified by extensively analyzing the inaccuracy of measurement and subsequently employed to weight the measured quantities.
Go to article

Abstract

Power systems that are highly loaded, especially by a stochastic supply of renewables and the presence of storages, require dynamic measurements for their optimal control. Phasor measurement units (PMUs) can be used to capture electrical parameters of a power system. Standards on the PMU dynamic performance have been modified to incorporate their new dynamic mode of operation. This paper examines the PMU dynamic performance and proposes essential algorithms for measurement accuracy verification. Measurements of dynamic input signals, which vary in amplitude or frequency, were taken during automated tests of two PMUs. The test results are presented and expounded with further recommendation for the performance requirements. This paper also presents and examines applied testing procedures with relevance to the specifications of the IEEE Standard for Synchrophasor C37.118.1™-2011 and its amendment C37.118.1a™-2014.
Go to article

This page uses 'cookies'. Learn more