Abstract

High voltage direct current (HVDC) emergency control can significantly improve the transient stability of an AC/DC interconnected power grid, and is an important measure to reduce the amount of generator and load shedding when the system fails. For the AC/DC interconnected power grid, according to the location of failure, disturbances can be classified into two categories: 1) interconnected system tie-line faults, which will cause the power unbalance at both ends of the AC system, as a result of the generator rotor acceleration at the sending-end grid and the generator rotor deceleration at the receiving-end grid; 2) AC system internal faults, due to the isolation effect of the DC system, only the rotor of the generator in the disturbed area changes, which has little impact on the other end of the grid. In view of the above two different locations of disturbance, auxiliary power and frequency combination control as well as a switch strategy, are proposed in this paper. A four-machine two-area transmission system and a multi-machine AC/DC parallel transmission system were built on the PSCAD platform. The simulation results verify the effectiveness of the proposed control strategy.
Go to article

Abstract

Persistent organic pollutants (POPs) originating from agrochemical industries have become an urgent environmental problem worldwide. Ordinary kriging, as an optimal geostatistical interpolation technique, has been proved to be sufficiently robust for estimating values with finite sampled data in most of the cases. In this study, ordinary kriging interpolation integrate with 3D visualization methods is applied to characterize the monochlorobenzene contaminated soil for an agrochemical industrial site located in Jiangsu province. Based on 944 soil samples collected by Geoprobe 540MT and monitored by SGS environmental monitoring services, 3D visualization in terms of the spatial distribution of pollutants in potentially contaminated soil, the extent and severity of the pollution levels in different layers, high concentration levels and isolines of monochlorobenzene concentrations in this area are provided. From the obtained results, more information taking into account the spatial heterogeneity of soil area will be helpful for decision makers to develop and implement the soil remediation strategy in the future.
Go to article

Abstract

This paper describes the design and test of a new high-current electronic current transformer based on a Rogowski coil. For better performances, electronic current transformers are used to replace conventional electro-magnetic inductive current transformers based on ferromagnetic cores and windings to measure high-current on the high voltage distribution grids. The design of a new high-current electronic current transformer is described in this paper. The principal schemes of the prototype and partial evaluation results are presented. Through relative tests it is known that the prototype has a wide dynamic range and frequency band, and it can allow high accuracy measurements.
Go to article

Abstract

Electronic voltage transformers (EVT) and electronic current transformers (ECT) are important instruments in a digital substation. For simple, rapid and convenient development, the paper proposed an on-site calibration system for electronic instrument transformers based on LabVIEW. In the system, analog signal sampling precision and dynamic range are guaranteed by the Agilent 3458A digital multimeter, and data synchronization is also achieved based on a self-developed PCI synchronization card. To improve the measurement accuracy, an error correction algorithm based on the Hanning window interpolation FFT has good suppression of frequency fluctuation and inter-harmonics interference. The human-computer interface and analysis algorithm are designed based on LabVIEW, and the adaptive communication technology is designed based on IEC61850 9-1/2. The calibration system can take into account pairs of digital output and analog output of the electronic voltage/current transformer calibration. The results of system tests show that the calibration system can meet the requirements of 0.2 class calibration accuracy, and the actual type test and on-site calibration also show that the system is easy to operate with convenience and satisfactory stability.
Go to article

Abstract

Considering the low efficiency during the process of traditional calibration for digital-display vibrometers, an automatic calibration system for vibrometers based on machine vision is developed. First, an automatic vibration control system is established on the basis of a personal computer, and the output of a vibration exciter on which a digital-display vibrometer to be calibrated is installed, is automatically adjusted to vibrate at a preset vibration level and a preset frequency. Then the display of the vibrometer is captured by a digital camera and identified by means of image recognition. According to the vibration level of the exciter measured by a laser interferometer and the recognized display of the vibrometer, the properties of the vibrometer are calculated and output by the computer. Image recognition algorithms for the display of the vibrometer with a high recognition rate are presented, and the recognition for vibrating digits and alternating digits is especially analyzed in detail. Experimental results on the built-up system show that the prposed image recognition methods are very effective and the system could liberate operators from boring and intense calibration work for digital-display vibrometers
Go to article

Abstract

In this paper, we propose a new method of measuring the target velocity by estimating the scaling parameter of a chaos-generating system. First, we derive the relation between the target velocity and the scaling parameter of the chaos-generating system. Then a new method for scaling parameter estimation of the chaotic system is proposed by exploiting the chaotic synchronization property. Finally, numerical simulations show the effectiveness of the proposed method in target velocity measurement.
Go to article

Abstract

To keep genetic diversity, flowering plants have developed a self-incompatibility system, which can prevent self-pollination. It has been reported that calcium concentration in pistil papilla cells was increased after self-pollination in transformed self-incompatible Arabidopsis thaliana. In this study, we found that CML27 changed its expression level for both mRNA and protein when compared to transcriptome and proteome. At the same time, CML27 was expressed in the anther and pistil at a high level and reached up to 5-fold up-regulated expression in the pistil at 1 h post-pollination when compared to 0 min. In order to find out potential proteins that may interact with BoCML27, BoCML27 was expressed in and isolated from E. coli. After its co-incubation with Brassica oleracea pistil proteins, the products were separated on SDS-PAGE gels. We found a specific band at the position between 130–180 kDa. Through LC-MS-MS (Q-TOF) analysis, eight proteins were identified from the band. The proteins include 26S proteasome non-ATPase regulatory (26S), Phospholipase D, alpha 2 (PLDα2) involved in Ca2+ binding and Coatomer subunit alpha-2-like (Coatomer) involved in vesicle mediated transport. All of these identified proteins provide new insights for the self-incompatibility response in B. oleracea, specific for increasing Ca2+ concentration in pistil papilla cells.