Search results

Filters

  • Journals
  • Date

Search results

Number of results: 13
items per page: 25 50 75
Sort by:

Abstract

Photovoltaic panels have a non-linear current-voltage characteristics to produce the maximum power at only one point called the maximum power point. In the case of the uniform illumination a single solar panel shows only one maximum power, which is also the global maximum power point. In the case an irregularly illuminated photovoltaic panel many local maxima on the power-voltage curve can be observed and only one of them is the global maximum. The proposed algorithm detects whether a solar panel is in the uniform insolation conditions. Then an appropriate strategy of tracking the maximum power point is taken using a decision algorithm. The proposed method is simulated in the environment created by the authors, which allows to stimulate photovoltaic panels in real conditions of lighting, temperature and shading.
Go to article

Abstract

This paper presents a new modification of the least-squares Prony’s method with reduced sampling, which allows for a significant reduction in the number of the analysed signal samples collected per unit time. The specific combination of non-uniform sampling with Prony’s method enables sampling of the analysed signals at virtually any average frequency, regardless of the Nyquist frequency, maintaining high accuracy in parameter estimation of sinusoidal signal components. This property allows using the method in measuring devices, such as for electric power quality testing equipped with low power signal processors, which in turn contributes to reducing complexity of these devices. This paper presents research on a method for selecting a sampling frequency and an analysis window length for the presented method, which provide maximum estimation accuracy for Prony’s model component parameters. This paper presents simulation tests performed in terms of the proposed method application for analysis of harmonics and interharmonics in electric power signals. Furthermore, the paper provides sensitivity analysis of the method, in terms of common interferences occurring in the actual measurement systems.
Go to article

Abstract

This article presents a way of analyzing the transfer function of electronic signal amplifiers. It also describes the possibility of using signal precorrection which improves the parasitic harmonics in the THD (Total Harmonic Distortion) of the amplified signal by correcting linearity of the tested amplifier’s transfer function. The proposed method of analyzing and presenting the transfer function allows to diagnose the causes of generating parasitic harmonics, what makes it a useful tool when designing low distortion amplifier systems, such as e.g. amplifiers in measurement systems. The presented THD correction can be used in e.g. amplifier systems that cooperate with arbitrary generators.
Go to article

Abstract

This paper presents an example of practical use of Prony's method for monitoring of power waveform fundamental harmonic fluctuations, which is required for the analysis of window synchronizations in frequency analyses in power monitoring systems. The example presented offers verification of the authors' theoretical considerations published earlier in articles about Prony's method and its opportunities for practical use for real life signals. The investigations shown are based on the least squares Prony's method, which, in connection with digital filtrations, enables estimations of fundamental frequency at the rate of even tens of times per one fundamental harmonic period.
Go to article

Abstract

The article presents an application of Prony’s method with some known components in the analysis of electric power quality. Modifications of the Prony algorithm broaden the scope of method application. Modification of the filter of known components enables more accurate analysis of the parameters of unknown components and components with known or assumed frequencies. This article presents a comparison of the results of analyses conducted with the proposed algorithm for simulated and real signals and the results obtained by means of a commercial electric power quality testing device, operating in class A and using the Fourier transform. The proposed method enables to estimate the levels of the harmonic components, the frequency of the fundamental signal and real parameters of the interharmonic components, which are grouped and averaged in the contemporary monitoring equipment. Knowledge of the individual parameters of the interharmonics has considerable diagnostic importance while removing causes of incorrect operation affecting sensitive equipment in some electric power systems. Additionally, the algorithm is capable of analyzing exponentially damped components and finds its application in analysis of disturbances, for example, transient oscillations.
Go to article

Abstract

The article presents a new modification of the the least squares Prony method. The so-called variable-frequency Prony method can be a useful tool for estimating parameters of sinusoidal components, which, in the analyzed signal, are characterized by time-dependent frequencies. The authors propose use of the presented method for testing the quality of electric energy. It allows observation of phenomena which, when using traditional methods, are averaged in the analysis window. The proposed modification of least squares Prony method is based on introduction and specific selection of a frequency matrix. This matrix represents frequencies of estimated components and their variability in time.
Go to article

Abstract

The paper deals with frequency estimation methods of sine-wave signals for a few signal cycles and consists of two parts. The first part contains a short overview where analytical error formulae for a signal distorted by noise and harmonics are presented. These formulae are compared with other accurate equations presented previously by the authors which are even more accurate below one cycle in the measurement window. The second part contains a comparison of eight estimation methods (ESPRIT, TLS, Prony LS, a newly developed IpDFT method and four other 3-point IpDFT methods) in respect of calculation time and accuracy for an ideal sine-wave signal, signal distorted by AWGN noise and a signal distorted by harmonics. The number of signal cycles is limited from 0.1 to 3 or 5. The results enable to select the most accurate/ fastest estimation method in various measurement conditions. Parametric methods are more accurate but also much slower than IpDFT methods (up to 3000 times for the number of samples equal to 5000). The presented method is more accurate than other IpDFT methods and much faster than parametric methods, which makes it possible to use it as an alternative, especially in real-time applications.
Go to article

Abstract

Fast and accurate grid signal frequency estimation is a very important issue in the control of renewable energy systems. Important factors that influence the estimation accuracy include the A/D converter parameters in the inverter control system. This paper presents the influence of the number of A/D converter bits b, the phase shift of the grid signal relative to the time window, the width of the time window relative to the grid signal period (expressed as a cycle in range (CiR) parameter) and the number of N samples obtained in this window with the A/D converter on the developed estimation method results. An increase in the number b by 8 decreases the estimation error by approximately 256 times. The largest estimation error occurs when the signal module maximum is in the time window center (for small values of CiR) or when the signal value is zero in the time window center (for large values of CiR). In practical applications, the dominant component of the frequency estimation error is the error caused by the quantization noise, and its range is from approximately 8×10-10 to 6×10-4.
Go to article

Abstract

The one-dimension frequency analysis based on DFT (Discrete FT) is sufficient in many cases in detecting power disturbances and evaluating power quality (PQ). To illustrate in a more comprehensive manner the character of the signal, time-frequency analyses are performed. The most common known time-frequency representations (TFR) are spectrogram (SPEC) and Gabor Transform (GT). However, the method has a relatively low time-frequency resolution. The other TFR: Discreet Dyadic Wavelet Transform (DDWT), Smoothed Pseudo Wigner-Ville Distribution (SPWVD) and new Gabor-Wigner Transform (GWT) are described in the paper. The main features of the transforms, on the basis of testing signals, are presented.
Go to article

Abstract

We introduce numerical methods and algorithms to estimate the main parameters of fractal-like particle aggregates from their optical structure factor (i.e. light scattering diagrams). The first algorithm is based on a direct and simple method, but its applicability is limited to aggregates with large size parameter and intermediate fractal dimension. The second algorithm requires to build calibration curves based on accurate particle agglomeration and particle light scattering models. It allows analyzing the optical structure factor of much smaller aggregates, regardless of their fractal dimension and the size of the single particles. Therefore, this algorithm as well as the introduction of a criterial curve to detect the different scattering regimes, are thought to be powerful tools to perform reliable and reproducible analysis.
Go to article

Abstract

Telemedicine is one of the most innovative and promising applications of technology in contemporary medicine. Telemedical systems, a sort of distributed measurement systems, are used for continuous or periodic monitoring of human vital signals in the environment of living. This approach has several advantages in comparison to traditional medical care: e.g. patients experience fewer hospitalizations, emergency room visits, lost time from work, the costs of treatment are reduced, and the quality of life is improved. Currently, chronic respiratory diseases comprise one of the most serious public health problems. Simultaneously patients suffering from these diseases are well suitable for home monitoring. This paper describes the design and technical realization of a telemedical system that has been developed as a platform suitable for monitoring patients with chronic pulmonary diseases and fitted to Polish conditions. The paper focuses on the system's architecture, included medical tests, adopted hardware and software, and preliminary internal evaluation. The performed tests demonstrated good overall performance of the system. At present further work goes on to put it into practice.
Go to article

Abstract

Background: Recoarctation (reCoA) of the aorta is a common complication after the Norwood procedure. Untreated, it can lead to failure of the systemic ventricle and death. The main goal of the study is to defi ne risk factors of reCoA after the Norwood procedure in hypoplastic left heart syndrome (HLHS). Methods: We retrospectively analyzed the pre-, intra- and postoperative data of 96 successive patients who underwent the Norwood procedure between 2007 and 2011. In case of reCoA balloon angioplasty was performed. We analyzed and compared the data of the patients with reCoA and without reCoA using the StatSoft STATISTICA™ 10 soft ware. Results: ReCoA was noted in 23 patients (33.3%). Th is complication was diagnosed 95.1 days (49–156 days) on the average aft er the Norwood procedure. Balloon angioplasty successfully allowed for decreasing the mean gradient across the site of the narrowing from the average 27.5 mmHg to the average 9.7 mmHg (p = 0.008) and enlarged the neo-isthmus by the average of 2 mm (p <0.05). Th e risks factors seemed to be the diameter of the ascending aorta OR = 7.82 (p = 0.001), atresia of the mitral valve OR = 7.00 (p = 0.003) and atresia of the aortic valve — OR = 6.22 (p = 0.002). Conclusion: Balloon angioplasty seems to be an eff ective intervention in case of reCoA. A low diameter of the native ascending aorta (≤3mm) and the presence of atresia of the mitral and/or aortic valve should intensify the vigilance of a cardiologist in the search for signs of reCoA of the aorta.
Go to article

Abstract

T h e a i m: The aim of the study is to present the initial experience with continuous flow left ventricle assist device (CF-LVAD) in pediatric patients with BSA below 1.5 m2. M a t e ri a l a n d M e t h o d s: Between 2016 and 2017, CF-LVAD (the Heartware System) have been implanted in three pediatric patients in the Department of Pediatric Cardiac Surgery, Jagiellonian University, Krakow, Poland. The indications for initiating CF-LVAD were end-stage congestive heart failure due to dilated cardiomyopathy in all children. R e s u l t s: Implanted patients have had BSA of 1.09, 1.42, 1.2 m2, and 37, 34, 34 kg of body weight and the age 12, 11, 12 years, respectively. The time of support was 550 days in two patients and 127 in another one, and is ongoing. The main complication has been driveline infection. C o n c l u s i o n: The outcomes from our single-center experience using the HeartWare CF-LVAD have been excellent with a low incidence of complication and no necessity to reoperation in our patients. Children could be successfully and safely discharged home.
Go to article

This page uses 'cookies'. Learn more