Search results

Filters

  • Journals
  • Date

Search results

Number of results: 12
items per page: 25 50 75
Sort by:

Abstract

While the Slope Fault Model method can solve the soft-fault diagnosis problem in linear analog circuit effectively, the challenging tolerance problem is still unsolved. In this paper, a proposed Normal Quotient Distribution approach was combined with the Slope Fault Model to handle the tolerances problem in soft-fault diagnosis for analog circuit. Firstly, the principle of the Slope Fault Model is presented, and the huge computation of traditional Slope Fault Characteristic set was reduced greatly by the elimination of superfluous features. Several typical tolerance handling methods on the ground of the Slope Fault Model were compared. Then, the approximating distribution function of the Slope Fault Characteristic was deduced and sufficient conditions were given to improve the approximation accuracy. The monotonous and continuous mapping between Normal Quotient Distribution and standard normal distribution was proved. Thus the estimation formulas about the ranges of the Slope Fault Characteristic were deduced. After that, a new test-nodes selection algorithm based on the reduced Slope Fault Characteristic ranges set was designed. Finally, two numerical experiments were done to illustrate the proposed approach and demonstrate its effectiveness.
Go to article

Abstract

A new soft-fault diagnosis approach for analog circuits with parameter tolerance is proposed in this paper. The approach uses the fuzzy nonlinear programming (FNLP) concept to diagnose an analog circuit under test quantitatively. Node-voltage incremental equations, as constraints of FNLP equation, are built based on the sensitivity analysis. Through evaluating the parameters deviations from the solution of the FNLP equation, it enables us to state whether the actual parameters are within tolerance ranges or some components are faulty. Examples illustrate the proposed approach and show its effectiveness.
Go to article

Abstract

In the acoustic fatigue experiment for hypersonic vehicle in simulated harsh service environment on ground, acoustic loads on the surface of test pieces of the vehicle need to be measured. However, for the normal microphones without high temperature resistance ability, the near field sound measurement cannot be achieved. In this work, on the basis of previous researches, an acoustic tubes array is designed to achieve the near field measurement of acoustic loads on the surface of the test piece in the supersonic airflow with high temperature achieved by coherent jet oxygen lance. Firstly, the process of designing this acoustic tubes array is introduced. Secondly, the equality of phase differences at the front and at the end of the tubes is stated and proved using a phase differences test with an acoustic tubes array whose design is presented in this text; therefore, the phase differences of signals acquired by microphones can be directly applied to beamforming algorithm to determine the acoustic load source. Finally, using above mentioned acoustic tubes array, measurement of acoustic load, with and without a test piece in the supersonic airflow made by the coherent jet oxygen lance, is conducted respectively, and the measurements results are analyzed.
Go to article

Abstract

Lower Carboniferous limestone has been extracted in the “Czatkowice” open-pit hill-slope quarry in southern Poland since 1947, for the needs of metallurgical and building industries, as well as farming. We can distinguish two aquifers in the Czatkowice area: the Quaternary porous aquifer and the Carboniferous fissure-porous one. Two vertical zones representing different hydrodynamic characteristics can be indentified in the Carboniferous formations. One is a weathering zone and the other one the zone of fissures and interbedding planes. Groundwater inflows into the quarry workings have been observed at the lowest mining level (+315 m above the sea level (asl)) for over 30 years. This study concerns two hypotheses of the sources of such inflows originating either from (a) the aeration zone or from (b) the saturation zone. Inflows into the quarry combine into one stream flowing gravitationally to the doline under the pile in the western part of the quarry. This situation does not cause a dewatering need. Extending eastward mining and lowering of the exploitation level lead to increased inflows.
Go to article

Abstract

In this paper, crushability of foundry sand particles was studied. Three kinds of in-service silica sands in foundry enterprises selected as the study object, and foundry sand particles were subjected to mechanical load and thermal load during service were analyzed. A set of methods for simulating mechanical load and thermal load by milling and thermal-cold cycling were designed and researched, which were used to characterize the crushability for silica sand particles, the microstructure was observed by SEM. According to the user’s experience in actual application, the crushability of Sand C was the best and then Sand B, the last Sand A. The results indicated that mechanical load, thermal load and thermal-mechanical load can all be used to characterize the crushability of foundry sand particles. Microscopic appearances can qualitatively characterize the crushability of foundry sand particles to a certain extent, combining with the additions and cracks which are observed on the surface.
Go to article

This page uses 'cookies'. Learn more